Customization: | Available |
---|---|
Connection Form: | Bolt Connection |
Window: | Plastic Steel Window |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. | Sort | Name | Specification: |
1 | Specification | length | No limited |
2 | Width | Less than 11m | |
3 | Wall height | 2600mm/2800mm | |
4 | Clear height | 2600mm/2800mm | |
5 | Roof slope | 15° | |
6 | Standard accessory | Wall board | 75mm thickness double color-steel sandwich panel with polystyrene foam inside. Heat Insulated coefficient is 0.041w/m.k. Heat transfer coefficient is 0.546w/ m².k. |
7 | False ceiling | 75mm thickness double color-steel sandwich panel with polystyrene foam inside. Heat Insulated coefficient is 0.041w/m.k. Heat transfer coefficient is 0.546w/ m².k. | |
8 | Roof board | color steel corrugated sheet, 0.5mm thickness | |
9 | Outside door | Security door, single door with dimensions of 900*2100mm, furnished with a handle lock with 3keys. Doorframe is made of 1.2mm steel, and door is made of 0.7 mm steel, 90mm thick rock wool insulation foam. | |
10 | Inside door | SIP, single door with dimensions of 750*2000mm, furnished with a cylinder lock with 3keys. Doorframe is made of aluminum, 50mm thick EPS insulation foam. | |
11 | Window(W-1) | PVC, white color, with dimensions of 1200*1200mm, glazed with glass in a thickness of 5mm, two bay fixed, and two bay sliding, supplied with fly screen. | |
12 | Window(W-2) | PVC, white color, with dimensions 500*500mm, glazed with glass in a thickness of 5mm, casement opening, supplied with fly screen. | |
13 | Channel | Galvanized Steel Plain Sheet press moulding Material: Q235. Painted | |
14 | Post | Square steel tube Material: Q235. Painted | |
15 | Purline | Square steel tube Material: Q235. Painted | |
16 | Roof truss | Square steel tube Material: Q235. Painted | |
17 | Decoration and connection | color steel sheet, 0.35mm thickness | |
18 | Option | Decorative floor | PVC, laminated or ceramic tile |
19 | Drainage system | Provided plan, design and construction | |
20 | Electric system | Provided plan, design and construction | |
21 | Technical parameter | Bearing load | 30kg/m2 |
22 | Wind pressure: | 0.45KN/M2 | |
23 | Fire proof | B2 grade | |
24 | Resistant temperature | -20 ºC to 50º |
1 | Location (where will be built?) | _____country, area |
2 | Size: length*width*height | _____mm*_____mm*_____mm |
3 | wind load (max. wind speed) | _____kn/m2, _____km/h, _____m/s |
4 | snow load (max. snow height) | _____kn/m2, _____mm |
5 | anti-earthquake | _____level |
6 | brickwall needed or not | If yes, 1.2m high or 1.5m high |
7 | thermal insulation | If yes, EPS, fiberglass wool, rockwool, PU sandwich panels will be suggested; . if not, the metal steel sheets will be ok. The cost of the latter will be much lower than that of the former |
8 | door quantity & size | _____units, _____(width)mm*_____(height)mm |
9 | window quanity & size | _____units, _____(width)mm*_____(height)mm |
10 | crane needed or not | If yes, _____units, max. lifting weight____tons; max. lifting height _____m |